Specification #FI 1190
FACTORY OUTDOOR INSULATION SPECIFICATION

(Sprayed-On Polyurethane Foam With Topcoat)

All Hanson water storage tanks are offered with optional spray-on polyurethane foam factory insulation with topcoat. Nominal "R" value is R-16 @ 2" thick. This exceeds ASHRAE requirements.

Hanson factory insulation is a 2 component HCFC blown, polyurethane spray foam system. The foam is rated CLASS I according to ASTM E-84 at two inches, flame spread index 25 with 345 smoke developed.

The product is designed for use in applications where the stringent requirements for a Class I system must be met. Its outstanding physical properties result in LTS exceptional fire resistance.

(Information taken from the manufacturer's product information and subject to change without notice)


Installed Density:

1.7 - 2.0 PCF

Compressive Strength:

22 -28 psi

Tensile Strength:

40 - 45 psi

R. Value:

7.11 per Inch (R-16 = 2 1/4")

Closed Cell Content:

Over 90%

Weight:

2 lbs/cu ft

Max thickness:

4" (R -28)

Topcoat:

2 coats (min. 23 mils D.F.T)
White acrylic coating

Undercoat: (optional)

1 coat (2-3 mils D.F.T.) inorganic zinc primer

UV Resistance:

Excellent (ASTM D-1499)

Reflective index:

90%

Stability:

Excellent to 210 degree F (ASTM - 794)

Water Permeability:

Zero after 21 days immersion

Solids:

58.7% by volume


Note: Hanson R-16 foam outdoor tank insulation is an effective alternative to metal jacketed tanks at about 70% saving for the same R. Value. Any minor shipping damage can easily be repaired in the field with no effect on performance or durability.

Before system startup and periodically during service, the topcoat should be examined and repaired if necessary. This is essential if the vessel is outdoors, in which case we also recommend inorganic zinc tank primer at extra cost.